SALT-3100AS0003 version 1.0 (26 Feb 2003) Specifications for the Slitmask Cutter for the Prime Focus Imaging Spectrograph of the Southern African Large Telescope. Description: The Space Astronomy Laboratory will pruchase a precision laser cutting system to manufacture slitmasks for the Prime Focus Imaging Spectrograph. This system (referred to in the trade as a micro-machining unit) will consist of a laser head, focusing optics, a precision x-y stage, and associated computer interface to control coordinated laser operation and x-y stage movement. Laser: A 2-8 W Continuous Wave Nd:YAG laser operating at 532 nm in TEM00 mode. Beam Size: 15 micron focused spot size. X-Y stage minimum specs: 150 mm total end-to-end travel 1 kg load capacity Stage accuracy 10 microns Repeatability +/- 1 micron Straightness and flatness +/- 4.0 microns (max) differential 1.0 micron/25 mm Orthogonality 20 arcsec Cutting rate: 20mm/minute